Digital Flow Fuel Delivery Gun |
Great simple re-fueling
nozzle fitted with a in-line digital meter
is designed for factories, coach yard, gas station and household use.
Allows you to deliver fuel through a digital meter display. Supplied
with an adaptor suitable for 1" BSPF ports. Easy to clean, install and
maintain. For different country use, the meter comes with 4 unit options
Liters (L) / Gallons (GAL) / Pints (PT) / Quarts (QT).
This
flow meter has circle function ,when it mass this scale, it will start
from the zero again. The battery inside can supply 9000hours operation
approximately.
Two main Button: CALIBRATE from which you can choose the
right measuring unit you need and display the total volume and DISPLAY
from which you can change the PER TIME volume to be zero.
Color of guns will be shipped at random, red, black, long-term supply.
|
Pick-up Location:
Warehouse & Showroom 9917 Gidley Street, Unit B El Monte, CA 91731 United States
* Before pickup, please call us to make sure. Business Hours Monday - Friday
8:00am--5:00pm Tel: 626 – 415 6138
Note: If you are International customer out of Canada or USA, please contact
with us for consulting the detailed shipping information.
|
Maximum Display: |
9999.9 liters |
Port: |
1" BSPF |
Housing: |
Aluminum & Plastic |
Nozzle size: |
1''
|
Operating Flowing range : |
15-75L/min |
Accuracy (% of Reading): |
± 0.5%
|
Maximum working pressure : |
0.25Mpa |
Minimum working pressure : |
0.1Mpa |
Operating Temperature Range: |
-10°C to 60°C
|
Powered by:
|
2 x AAA batteries. Approx Life 9000hrs |
|
|
|
1. Portable
lightweight and durable
2.
Economic environmental protection use.
3.
High sensitive dispay
4.The nozzle is punch-formed at one time.
5.Simple operation, long service life, brand new,
comfortable to use
|
Applications: |
Suitable for Fuel ,Gasoline, Kerosene
Diesel ,Petrol and so on. |
Reset to “0”
Press “DISPLAY” for 1 second reset to zero.
Cumulative Total
Press “CALIBRATE” indicating the cumulative total fueling. When the
cumulative total reaches a maximum reading 999,999, it will
automatically reset to zero.
Calibrate adjusting
Press“CALIBRATE” and hold for 3 seconds, press “DISPLAY” or “CALIBRATE”
for adjusting. For example, when the meter shows 103L while the liquid
comes 100L put the figure 103/100=1.0300. And the computer display is
programmed to turn back to stand-by situation after 5 seconds.
Units Switch
Press“ CALIBRATE” and hold for 3 seconds, press “DISPLAY” for 5 times
and then press“ CALIBRATE” for units switch among Liters (L) / Gallons
(GAL) / Pints (PT) / Quarts (QT). . And the computer display is
programmed to turn back to stand-by situation after 5 seconds. |
|
|
The meter is virtually
maintenance-free. However, it is important to make sure that the rotor
moves freely. Keep the display clean and free of contaminants. If the
rotor does not turn freely, apply a penetrating lubricant on the rotor,
shaft, and bearings. Remove any debris or deposits from the rotor by
using a soft brush or small probe. Be careful not to damage the turbine
rotor or supports. Replace batteries when “L Bat” comes. For the most
accurate display, make sure there is no air in the system before using
and meet the gun’s minimum flow rate requirements. |
Item included(190050): |
1*Digital Flow Fuel Delivery Gun
1*Adaptor
|
|